Accessories for level sensors.

Automatic Tank Level Management
Service stations and fuel depots

Optional Kits

[1]
Density Module

Size: 2” Construction: AISI 316 Gasoline and diesel versions available Accuracy: ± 2 kg/m³

[2]
Continuous density kit

Sizes: 2”, 2½”, 4” Suitable for rigid and flexible level sensors (AISI 316) High resolution Minimal dead zone Accuracy: ± 1 kg/m³ OIML R85 laboratory certified

[3]
Phase Separation Kit

Size: 2” Construction: AISI 316 This module detects the presence of gasoline/water mixture and water accumulation at the bottom of the tank.

Accessories for Ex ia wired level sensors.

[4]
DCB_2AWG24+2AWG18_IS

Ex ia Cable 2x1+2x0.5 twisted, shielded and fuel-resistant ENI 00.181.00 Blue color, RAL 5005. Specifically designed for Alisonic Ex ia level sensors.

[2]
JB-SI 3

Three-way IP68 junction box for Ex ia level indicators.

[3]
JB-SI

Two-way IP68 junction box for Ex ia level indicators.

[5]
CAP - Riser

2” female riser cap.

Accessories for Ex d wired level sensors.

[1]
JB-Exd

Ex d IP68 junction box complete with two plugs and three cable glands, suitable for two- or three-way configuration.

[6]
DCB_2AWG24+2AWG18_EX

Exd wiring cable 2x1+2x0.5 twisted, shielded and fuel-resistant ENI 00.181.00 Grey color, RAL 701. Specifically designed for Alisonic Ex d level sensors.

[3]
Probe Protection

Head protection cover for Ex d level sensors.

Accessories for wireless level sensors.

[5]
BATT-SI-RF

Lithium battery for Ex ia wireless level sensors.

[6]
CAP RISER W-R

2” F delrin cap riser for wireless level gauges.

Accessories for consoles

Marking ATEX: TÜV IT 24 ATEX 0209 X

II (1)G [Ex ia Ga] IIB

Safe Link

Active intrinsically safe barrier for Probe in Zone 0

• Intrinsically safe galvanic isolation barrier, suitable for powering bus circuits in Zone 0 (1G) 
• Circuit protection and current line stabilization
• Supports connection of up to 8 probes per barrier
• Power supply: 12 V (±10%)
• RS485/RS232 communication interface

Marking ATEX: TÜV IT 24 ATEX 0231 X

II (1)G [Ex ia Ga] IIB

Safe Pass

Passive intrinsically safe barrier for Zone 0.

• Intrinsically safe barrier suitable for powering probes installed in Zone 0 (1G)
• Supports connection of up to 8 probes per barrier
• Power supply: 12 V (max 15.0 V)

EOS

• Wall-mounted printer
• Connectivity via RS232 or USB port
• High-speed printing, 200 dpi
• Paper width: 58 mm – roll Ø 50 mm
• Power supply: 220 Vac
• Internal memory: 4 MB

. Font internazionali disponibili
. Sensori di temperatura testina e presenza carta . Conformità UL CE FCC
. Ampio intervallo di temperatura: -20 ÷ +70 °C