Automatic Tank Level Management Service stations and fuel depots
Accessories
Optional Kits
[1]
Density Module
Size: 2”
Construction: AISI 316
Gasoline and diesel versions available
Accuracy: ± 2 kg/m³
[2]
Continuous density kit
Sizes: 2”, 2½”, 4”
Suitable for rigid and flexible level sensors (AISI 316)
High resolution
Minimal dead zone
Accuracy: ± 1 kg/m³
OIML R85 laboratory certified
[3]
Phase Separation Kit
Size: 2”
Construction: AISI 316
This module detects the presence of gasoline/water mixture and water accumulation at the bottom of the tank.
Accessories
Accessories for Ex ia wired level sensors.
[4]
DCB_2AWG24+2AWG18_IS
Ex ia Cable 2x1+2x0.5 twisted, shielded and fuel-resistant ENI 00.181.00 Blue color, RAL 5005.
Specifically designed for Alisonic Ex ia level sensors.
[2]
JB-SI 3
Three-way IP68 junction box for Ex ia level indicators.
[3]
JB-SI
Two-way IP68 junction box for Ex ia level indicators.
[5]
CAP - Riser
2” female riser cap.
Accessories
Accessories for Ex d wired level sensors.
[1]
JB-Exd
Ex d IP68 junction box complete with two plugs and three cable glands, suitable for two- or three-way configuration.
[6]
DCB_2AWG24+2AWG18_EX
Exd wiring cable 2x1+2x0.5 twisted, shielded and fuel-resistant ENI 00.181.00 Grey color, RAL 701.
Specifically designed for Alisonic Ex d level sensors.
[3]
Probe Protection
Head protection cover for Ex d level sensors.
Accessories
Accessories for wireless level sensors.
[5]
BATT-SI-RF
Lithium battery for Ex ia wireless level sensors.
[6]
CAP RISER W-R
2” F delrin cap riser for wireless level gauges.
Accessories
Accessories for consoles
Marking ATEX: TÜV IT 24 ATEX 0209 X
II (1)G [Ex ia Ga] IIB
Safe Link
Active intrinsically safe barrier for Probe in Zone 0
• Intrinsically safe galvanic isolation barrier, suitable for powering bus circuits in Zone 0 (1G) • Circuit protection and current line stabilization • Supports connection of up to 8 probes per barrier • Power supply: 12 V (±10%) • RS485/RS232 communication interface
Marking ATEX: TÜV IT 24 ATEX 0231 X
II (1)G [Ex ia Ga] IIB
Safe Pass
Passive intrinsically safe barrier for Zone 0.
• Intrinsically safe barrier suitable for powering probes installed in Zone 0 (1G) • Supports connection of up to 8 probes per barrier • Power supply: 12 V (max 15.0 V)
EOS
• Wall-mounted printer • Connectivity via RS232 or USB port • High-speed printing, 200 dpi • Paper width: 58 mm – roll Ø 50 mm • Power supply: 220 Vac • Internal memory: 4 MB
. Font internazionali disponibili . Sensori di temperatura testina e presenza carta . Conformità UL CE FCC . Ampio intervallo di temperatura: -20 ÷ +70 °C