COMPARE
- Product Overview
Example title
The Wireless Magnetostrictive Level Gauge is an intrinsically safe probe designed for advanced monitoring of underground tanks installed in Zone 0 environments. Using 169 MHz wireless magnetostrictive technology with an integrated battery, it ensures reliable long-distance transmission—up to 3 km—without the need for cabling or excavation. Built in stainless steel and equipped with high-precision floats, it accurately measures product level, water interface, and average temperature. Its compact design, fast installation, and long battery life—up to 7 years—make it a robust and efficient solution for demanding and highly regulated fuel storage applications.
- Compare models
Features
- Intrinsecally safe ZONE 0
- Explosion proof ZONE 1
- Enclosure
- IP68 up to 10m/24h
- Maximum height
- Serial RS485
Quality
- Accuracy ±0,25mm
- Resolution ±0,01mm
- Density accuracy ±1Kg/m³
- OIML R85 Certification
- Temp. accuracy ±0,2°C
- Water detection
- PHS detection
Protocols
- 6 digits
- 5 digits
- 5 digits old
- Modbus
- MTS
- Use of barrier is mandatory, either Passive or Active
Marcatura ATEX: TÜV IT 23 ATEX 0141
II 1G Ex ia IIB T4 Ga
Tamb.: -40°C ÷ +80°C
DF/IS
- AISI 316
- 6000mm
Quality
Protocols
Marcatura ATEX: TÜV IT 23 ATEX 0141
II 1G Ex ia IIB T4 Ga
Tamb.: -40°C ÷ +80°C
DW/IS
- AISI 316
- 6000mm
Quality
Protocols
Marcatura ATEX: TÜV IT 23 ATEX 0141
II 1G Ex ia IIB T4 Ga
Tamb.: -40°C ÷ +80°C
FX/IS
- AISI 316
- 25000mm
Quality
Protocols
Marcatura ATEX: TÜV IT 25 ATEX 0253 X
II 1/2G Ex h Ex db IIB T4 Ga/Gb
Tamb.: -40°C ÷ +70°C
DF/XS
- Alluminium
- 6000mm
Quality
Protocols
- Specifications
Marcatura ATEX: TÜV IT 23 ATEX 0141
II 1G Ex ia IIB T4 Ga
Tamb.: -40°C ÷ +80°C
Features
- Intrinsecally safe ZONE 0
- Explosion proof ZONE 1
- Enclosure
- IP68 up to 10m/24h (in water)
- Maximum height
- Serial RS485
Quality
- Accuracy ±0,25mm
- Resolution ±0,01mm
- Density accuracy ±1Kg/m³
- OIML R85 Certification
- Temp. accuracy ±0,2°C
- Water detection
- PHS detection
Protocols
- 6 digits
- 5 digits
- 5 digits old
- Modbus
- MTS
- Use of barrier is mandatory, either Passive or Active
Marcatura ATEX: TÜV IT 23 ATEX 0141
II 1G Ex ia IIB T4 Ga
Tamb.: -40°C ÷ +80°C
DF/IS
- AISI 316
- 6000mm
Quality
Protocols
Marcatura ATEX: TÜV IT 23 ATEX 0141
II 1G Ex ia IIB T4 Ga
Tamb.: -40°C ÷ +80°C
DW/IS
- AISI 316
- 6000mm
Quality
Protocols
Marcatura ATEX: TÜV IT 23 ATEX 0141
II 1G Ex ia IIB T4 Ga
Tamb.: -40°C ÷ +80°C
FX/IS
- AISI 316
- 25000mm
Quality
Protocols
Marcatura ATEX: TÜV IT 25 ATEX 0253 X
II 1/2G Ex h Ex db IIB T4 Ga/Gb
Tamb.: -40°C ÷ +70°C
DF/XD
- Alluminium
- 6000mm
Quality
Protocols